HLF12K-D48-H1000-B 12 kW Lightweight DC/DC Converter

I. Overview
HLF12K-D48-H1000-B high-voltage DC power supply is a light weight, high efficiency DCDC power supply. The maximum efficiency is ≥97%. HLF12K-D50-H1000-B Converts 800V - 1000V DC to 48VDC output, 12KW output power. Applied to under water robots.
HLF12K-D50-H1000-B is designed to meet power reliability requirements, including input undervoltage/overvoltage protection, output overvoltage protection, current limiting, short circuit protection, and over temperature protection.
4. Main Specifications
II. Environmental Conditions
| No. | Item | Technical Indicator | Unit |
|---|
| 1 | Operating Temperature | -40℃ ~ +55℃ | ℃ |
| 2 | Storage Temperature | -40℃ ~ +80℃ | ℃ |
| 3 | Relative Humidity | ≤95% (non-condensing at 40℃ ±2℃) |
|
| 4 | Altitude | 0-3000 m | m |
| 5 | Atmospheric Pressure | 76 ~ 106 | Kpa |
| 6 | Cooling Method | Built-in fan cooling |
|
III. Electrical Characteristics
1. Input Characteristics
| No. | Item | Technical Requirement | Unit |
|---|
| 1.1 | Rated Input Voltage | 950 | Vdc |
| 1.2 | Input Voltage Range | 800 ~ 1000 | Vdc |
| 1.3 | Maximum Input Current | 15 | A |
2. Output Characteristics
| No. | Item | Technical Requirement | Unit | Remarks |
|---|
| 2.1 | Rated Output Voltage | 48 | Vdc |
|
| 2.2 | Output Voltage Range | 46 ~ 52 | Vdc |
|
| 2.3 | Rated Output Current | 250 | A |
|
| 2.4 | Rated Output Power | 12 | KW |
|
| 2.5 | Output Efficiency | ≥97% |
| Vin=950Vdc, half load |
| 2.6 | Voltage Regulation Accuracy | ±1% |
|
|
| 2.7 | Source Regulation | ±1% |
|
|
| 2.8 | Load Regulation | ±1% |
|
|
| 2.9 | Output Ripple & Noise | ±2% of Vout |
| Bandwidth limit 20MHz, test with 10µF electrolytic capacitor and 0.1µF film capacitor in parallel; rated load |
| 2.10 | Temperature Coefficient | ±0.02% | /℃ |
|
| 2.11 | Output Rise Time | ≤200 | ms |
|
| 2.12 | Output Turn-on Delay | ≤5 | S | Rated input |
| 2.13 | On/Off Overshoot Amplitude | △V: ≤ ±5% |
|
|
| 2.14 | Dynamic Response Overshoot | △V: ≤ ±5% |
|
|
| 2.15 | Dynamic Response Recovery Time | ≤2 | ms | 25%~50%~25% or 50%~75%~50% load change, 25℃ |
3. Protection Characteristics
| No. | Item | Technical Requirement | Unit | Remarks |
|---|
| 3.1 | Input Under-Voltage Protection | ≤780 | Vdc | Hysteresis > 15V |
| 3.2 | Input Under-Voltage Recovery | 780 ~ 800 | Vdc |
|
| 3.3 | Input Over-Voltage Protection | ≥1020 | Vdc | Hysteresis > 15V |
| 3.4 | Input Over-Voltage Recovery | 1000 ~ 1020 | Vdc |
|
| 3.5 | Input Reverse Polarity Protection | No damage with reverse polarity |
| Input 800Vdc reverse connection |
| 3.6 | Output Over-Voltage Protection | 53 ~ 55 | Vdc | Self-recoverable |
| 3.7 | Output Over-Current Protection | 260 ~ 265 | A | Self-recoverable |
| 3.8 | Output Short-Circuit Protection | Yes |
| Self-recoverable |
| 3.9 | Over-Temperature Protection | 70 | ℃ | Case temperature |
| 3.10 | Over-Temperature Recovery | 60 | ℃ |
|
IV. Safety Characteristics
| No. | Item | Test Condition | Remarks |
|---|
| 1 | Dielectric Strength | Input to Output: 2500Vdc/10mA/1min | No arcing, no breakdown |
|
| Input to Case: 2500Vdc/10mA/1min |
|
|
| Output to Case: 500Vdc/10mA/1min |
|
| 2 | Insulation Resistance | Input to Output: ≥10MΩ @ 500Vdc | At normal atmospheric pressure, relative humidity 90%, test DC voltage 500V |
|
| Input to Case: ≥10MΩ @ 500Vdc |
|
|
| Output to Case: ≥10MΩ @ 500Vdc |
|
V. Mechanical Dimensions and Connector Definitions
1. Product Installation Dimension Diagram
VI. Order information
Part Number: HLF12K-D50-H1000-B
Size: 210mm x 240mm x 50mm±1mm